Loading

Testing & Laboratory

Plastics Testing

With its subgroups, experiments and associated standards.

Request a Quote

Scope

Subgroups within Plastics Testing

Each group lands in its own section on the same page; The full list of experiments is there.

Plastics tests

Plastics Testing — What Does This Testing Field Cover?

The section below describes how the field of Plastics Testing works. The conditions, sample requirements and acceptance criteria of the individual tests in this field are given on the relevant test pages.

Plastics testing determines the mechanical, thermal and burning behaviour of a polymer material. Unlike metals, plastics are VISCOELASTIC: their behaviour depends on loading rate, temperature and moisture. The same material therefore gives different results under different conditions, and the test conditions are an inseparable part of the result.

The practical consequence of viscoelasticity is this: a plastic part continues to deform over time under a constant load (creep) and the stress it carries at constant deformation falls over time (stress relaxation). A screwed joint loosens, a clamp loses its clamping force, a shelf sags over time. A short-term tensile test does not show this behaviour; a long-term test or an accelerated model is needed.

Thermal behaviour is the second main axis. Melt flow rate indicates the processability of the material and lot-to-lot consistency; heat deflection temperature and the Vicat softening point give a rough limit for service temperature. Thermal analysis (DSC, TGA, DMA) reveals the identity of the material: glass transition temperature, melting behaviour, crystallinity, filler content and decomposition temperature.

Burning behaviour is the third axis and ties directly into product standards. The UL 94 class and the limiting oxygen index are written into the material data sheet; a particular class is required for the housing of an electrical appliance, while a different classification system applies to a construction product.

Ageing is the most frequently skipped part of the field. Plastics degrade under UV, heat, moisture and oxygen: colour changes, the surface cracks, impact strength falls. For a part intended for outdoor use, what matters is not its values on day one but its values after ageing. Xenon arc and fluorescent UV equipment accelerate this degradation and allow comparison.

The output of this family is usually written into the material data sheet, and product standards refer to that sheet. But there can be a difference between the data sheet value and the behaviour of the actual part: orientation formed during moulding, weld lines and internal stresses make the part behave differently from the specimen.

The use of recycled content has added a new question to the field. Recycled resin varies from lot to lot; mechanical properties, colour and burning behaviour can shift between batches. For a manufacturer using recycled material, incoming material control is therefore not a choice but a necessity.

Method groups in this field

  • Mechanical

    Tension, compression, bending, Charpy and Izod impact, hardness (Shore), creep and environmental stress cracking.

  • Thermal

    Melt flow index (MFI), heat deflection temperature (HDT), Vicat softening temperature, linear thermal expansion.

  • Thermal analysis

    Transition temperatures and crystallinity by DSC, composition and decomposition by TGA, dynamic mechanical behaviour by DMA.

  • Burning

    UL 94 classification, limiting oxygen index (LOI), glow wire and needle flame tests.

  • Ageing

    Accelerated ageing by xenon arc and fluorescent UV, hot air ageing, humidity and condensation.

  • Physical

    Density, water absorption, ash content, gas and water vapour permeability of films and sheets.

Commonly confused in this field

  • A plastics result without a stated test rate and temperature cannot be interpreted; viscoelastic behaviour depends on these parameters.
  • A specimen result does not transfer directly to the actual part; moulding orientation and weld lines are decisive.
  • HDT and Vicat values are NOT service temperatures; they are a rough indication of an upper limit and do not apply under load.
  • The UL 94 class depends on thickness; a different wall thickness requires re-verification.
  • For moisture-absorbing polymers (such as polyamide), results are misleading unless conditioning is carried out.
  • ASTM D638 and ISO 527 results are not directly equivalent; the specimen geometries and rate definitions differ.

Which decisions these results support

  • Material selection and supplier approval
  • Meeting the flammability and thermal requirements of the product standard
  • Verifying the use of recycled content and lot control
  • Moulding process control and lot consistency
  • Demonstrating ageing resistance for outdoor use

Sectors

In which sectors is Plastics Testing used?

Plastics Testing quote

Tell us your product and the applicable standard; we'll share the timeline and sample requirements in writing.

Request a Quote

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy