Loading

Plastics Testing · Plastics tests

TGA

ISO 11358-1ASTM E1131ASTM D6370 (rubber composition analysis)
Plastics Testing laboratory work

What Is TGA?

Thermogravimetric analysis is a method in which the mass of the sample is continuously recorded while it is heated in a controlled atmosphere; It is an analysis method where decomposition temperatures, volatile matter, filler and ash content are determined.

Purpose of TGA

The aim is to determine the thermal stability of the polymer and the component ratios (volatile, polymer, carbon black, inorganic filler).

Which Products Is TGA Applied To?

  • Added and filled polymers
  • rubber compounds
  • Coatings and adhesives
  • Kompozit malzemeler

In Which Sectors Is TGA Used?

PlasticsAutomotivePackagingConsumer Products

Standards Related to TGA

  • ISO 11358-1
  • ASTM E1131
  • ASTM D6370 (rubber composition analysis)

TGA Conditions

Temperature program
Heating rate and temperature range defined in the standard or specification
Atmosfer
Inert (nitrogen) and, if necessary, oxidizing (air/oxygen) stages
sample mass
Defined in the standard; typically a few to a few tens of milligrams
Calibration
Temperature and mass calibration with certified references

Equipment for TGA

  • Thermogravimetric analyzer
  • Gas flow control system
  • Microbalance
  • Certified calibration materials

Sample Requirements for TGA

  • The sample must be representative and homogeneous
  • It should be placed thinly and evenly in the sample crucible.
  • Gas flow rate must be kept constant
  • Sample mass must be within the range defined in the standard

Duration of TGA

Typically 2–4 days.

TGA Procedure

  1. 1Device calibration is verified.
  2. 2The sample is weighed and placed in the crucible.
  3. 3Heating is applied in an inert atmosphere.
  4. 4If necessary, switch to oxidizing atmosphere.
  5. 5The mass loss curve and its derivative are evaluated.
  6. 6Component proportions are calculated.

TGA Acceptance Criteria

Acceptance criteria are the filler/ash ratio or decomposition onset temperature limits defined in the specification.

Evaluation of Results

Shifts heating rate and atmospheric decomposition temperatures; Comparison cannot be made without reporting these parameters. Separation of carbon black and inorganic filler requires atmospheric exchange; single-atmosphere analysis mixes the two.

TGA Report

  • Standard applied
  • Temperature program and atmosphere stages
  • sample mass
  • Mass loss steps and temperatures
  • Calculated ingredient ratios

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Material product standards

Plastics Testing — What Does This Testing Field Cover?

The section below describes the field that the TGA test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Plastics testing determines the mechanical, thermal and burning behaviour of a polymer material. Unlike metals, plastics are VISCOELASTIC: their behaviour depends on loading rate, temperature and moisture. The same material therefore gives different results under different conditions, and the test conditions are an inseparable part of the result.

The practical consequence of viscoelasticity is this: a plastic part continues to deform over time under a constant load (creep) and the stress it carries at constant deformation falls over time (stress relaxation). A screwed joint loosens, a clamp loses its clamping force, a shelf sags over time. A short-term tensile test does not show this behaviour; a long-term test or an accelerated model is needed.

Thermal behaviour is the second main axis. Melt flow rate indicates the processability of the material and lot-to-lot consistency; heat deflection temperature and the Vicat softening point give a rough limit for service temperature. Thermal analysis (DSC, TGA, DMA) reveals the identity of the material: glass transition temperature, melting behaviour, crystallinity, filler content and decomposition temperature.

Burning behaviour is the third axis and ties directly into product standards. The UL 94 class and the limiting oxygen index are written into the material data sheet; a particular class is required for the housing of an electrical appliance, while a different classification system applies to a construction product.

Ageing is the most frequently skipped part of the field. Plastics degrade under UV, heat, moisture and oxygen: colour changes, the surface cracks, impact strength falls. For a part intended for outdoor use, what matters is not its values on day one but its values after ageing. Xenon arc and fluorescent UV equipment accelerate this degradation and allow comparison.

The output of this family is usually written into the material data sheet, and product standards refer to that sheet. But there can be a difference between the data sheet value and the behaviour of the actual part: orientation formed during moulding, weld lines and internal stresses make the part behave differently from the specimen.

The use of recycled content has added a new question to the field. Recycled resin varies from lot to lot; mechanical properties, colour and burning behaviour can shift between batches. For a manufacturer using recycled material, incoming material control is therefore not a choice but a necessity.

Method groups in this field

  • Mechanical

    Tension, compression, bending, Charpy and Izod impact, hardness (Shore), creep and environmental stress cracking.

  • Thermal

    Melt flow index (MFI), heat deflection temperature (HDT), Vicat softening temperature, linear thermal expansion.

  • Thermal analysis

    Transition temperatures and crystallinity by DSC, composition and decomposition by TGA, dynamic mechanical behaviour by DMA.

  • Burning

    UL 94 classification, limiting oxygen index (LOI), glow wire and needle flame tests.

  • Ageing

    Accelerated ageing by xenon arc and fluorescent UV, hot air ageing, humidity and condensation.

  • Physical

    Density, water absorption, ash content, gas and water vapour permeability of films and sheets.

Commonly confused in this field

  • A plastics result without a stated test rate and temperature cannot be interpreted; viscoelastic behaviour depends on these parameters.
  • A specimen result does not transfer directly to the actual part; moulding orientation and weld lines are decisive.
  • HDT and Vicat values are NOT service temperatures; they are a rough indication of an upper limit and do not apply under load.
  • The UL 94 class depends on thickness; a different wall thickness requires re-verification.
  • For moisture-absorbing polymers (such as polyamide), results are misleading unless conditioning is carried out.
  • ASTM D638 and ISO 527 results are not directly equivalent; the specimen geometries and rate definitions differ.

Which decisions these results support

  • Material selection and supplier approval
  • Meeting the flammability and thermal requirements of the product standard
  • Verifying the use of recycled content and lot control
  • Moulding process control and lot consistency
  • Demonstrating ageing resistance for outdoor use

Related Tests

Frequently Asked Questions About TGA

According to which standard is TGA made?

TGA is executed in scope ISO 11358-1, ASTM E1131 and ASTM D6370 (rubber composition analysis). The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does TGA apply to?

Mainly applied to Added and filled polymers, rubber compounds, Coatings and adhesives and Kompozit malzemeler. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is TGA done?

The determining parameters are: Temperature program — Heating rate and temperature range defined in the standard or specification, Atmosfer — Inert (nitrogen) and, if necessary, oxidizing (air/oxygen) stages and sample mass — Defined in the standard; typically a few to a few tens of milligrams. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for TGA?

The sample must be representative and homogeneous, It should be placed thinly and evenly in the sample crucible. and Gas flow rate must be kept constant. The number of samples is determined according to the product standard and the scope to be reported.

How long does TGA take?

Typically 2–4 days. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the TGA result called "appropriate"?

Acceptance criteria are the filler/ash ratio or decomposition onset temperature limits defined in the specification.

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy