What Is Inspection?
In TOFD, the size of a flaw is computed from the time difference between signals produced when sound waves travelling between an opposed transmitter and receiver are diffracted at the flaw tips. Its distinguishing feature is that it relies on the arrival time of the diffracted signal, not on echo amplitude.
Why Is It Done?
The aim is to detect flaws in a weld and, above all, to measure flaw HEIGHT with high accuracy. That measurement is the input to fracture-mechanics based engineering critical assessment (ECA).
Which Equipment Is Covered?
- Butt welds of pressure equipment
- Pipeline girth welds
- Thick-walled weld seams
- Storage tank shell welds
- Monitoring of crack growth during service
Legal Basis and Interval
NDT has no interval of its own; how often it is applied follows the inspection programme it serves. In manufacturing the governing factor is the coverage required by the product standard and the specification (e.g. a given percentage of welds); in operation it is the asset integrity or risk-based inspection programme.
Scope of Inspection
- Volumetric and planar defects in the weld seam
- Measurement of through-wall defect height
- Defect length and depth location
- Root and surface defects (outside the dead zone)
- Monitoring of crack growth over time
Related Standards
- ISO/IEC 17020
- ISO 10863
- ISO 15626
- EN ISO 17640
- ISO 9712
Method and Equipment
- TOFD-capable ultrasonic instrument
- Transmitter and receiver probe pair and wedges
- Encoder and scanning rig
- Reference calibration blocks
- Couplant
- Data analysis software
Inspection Process
- 1Selection of Method and TechniqueThe type and location of the discontinuity sought and the material properties are assessed to select a suitable method and technique; a written procedure is prepared.
- 2Verification of Personnel and EquipmentThe level and industrial-sector qualification of the operator under EN ISO 9712 and the calibration records of the equipment are checked.
- 3Surface PreparationThe inspection surface is prepared as the method requires; coating, rust and contamination directly affect the sensitivity of the method.
- 4Calibration and Sensitivity VerificationA reference block or control specimen is used to demonstrate that the system can detect the discontinuity sought.
- 5Performing the InspectionScanning is carried out according to the procedure; indications are recorded and located.
- 6AssessmentIndications are evaluated against the applicable acceptance standard to determine whether they are defects; they are sized.
- 7ReportingMethod, technique, equipment, calibration, findings and acceptance criteria are reported together.
Nonconformities
Defects are located on the D-scan image, and their height is calculated from the time difference between diffraction signals. Acceptance is based on a standard such as ISO 15626 or on a fracture-mechanics-based assessment.
Inspection Report
- The inspection body and the personnel's EN ISO 9712 level and sector
- Method and technique applied and the written procedure number
- Part and weld examined, with a location sketch
- Equipment, consumables and calibration records
- Surface condition and inspection conditions
- Indications recorded, with their location and size
- Acceptance standard applied and the result of the evaluation
- Accept / reject decision
Accreditation
Non-destructive testing is carried out as an accredited inspection activity under ISO/IEC 17020. The second decisive factor in NDT is personnel qualification: the operator must be certified under EN ISO 9712 for the method, level and industrial sector concerned. An examination performed with a method outside the scope of that certificate is not valid. EUROLAB holds internationally recognised accreditation under ISO/IEC 17020, granted by accreditation bodies that are signatories to the ILAC mutual recognition arrangement.
Scope and authorisationsRelated Inspections
Frequently Asked Questions
What is the known weakness of TOFD?
Sensitivity drops in the region very close to the surface (the lateral-wave dead zone) and near the back wall. For this reason, TOFD is applied not alone but together with angled pulse-echo scanning (conventional UT or PAUT); each covers the other's blind spot.
Why is defect height so important?
Whether a defect threatens the structure depends less on its length than on how deep it extends through the wall. Fracture-mechanics-based acceptance assessment uses this height as an input; TOFD can provide this measurement with sub-millimetre accuracy.
Who may carry out the inspection?
NDT personnel are certified under EN ISO 9712 by method, level (1, 2, 3) and industrial sector. Level 1 performs the examination, Level 2 evaluates it and writes the report, Level 3 prepares procedures and selects the method. An examination performed in a method or sector outside the certificate is not valid.