What Is Temperature Rise — IEC 60335?

The temperature rise test is an electrical safety test in which the device is operated at rated conditions until steady state is reached, measuring the temperatures of components, windings, insulation and accessible surfaces.

Purpose of Temperature Rise — IEC 60335

The purpose is to verify that no component exceeds its insulation-class limit and no accessible surface exceeds the burn-risk limit.

Which Products Is Temperature Rise — IEC 60335 Applied To?

  • Household and similar appliances
  • Information-technology equipment
  • Lighting fixtures
  • Power supplies
  • Motor-driven appliances

In Which Sectors Is Temperature Rise — IEC 60335 Used?

ElectricalElectronicsMachineryMedical Device

Standards Related to Temperature Rise — IEC 60335

  • IEC 60335Safety in home and similar electrical devices test
  • IEC 62368Security in audio, video and information technology devices test
  • IEC 61010Safety in measuring, control and laboratory devices test

Temperature Rise — IEC 60335 Conditions

Supply
A multiple of rated voltage defined in the standard (typically 106% or the worst-case value)
Operating mode
The worst-case normal operating mode
Ambient temperature
Defined in the standard; measurements are corrected relative to this temperature
Stability
Temperatures must reach a state where they do not change over the defined period

Equipment for Temperature Rise — IEC 60335

  • Multi-channel temperature recording system
  • Thermocouples and resistance-method rig
  • Programmable AC source
  • Test corner or enclosure

Sample Requirements for Temperature Rise — IEC 60335

  • Thermocouple locations must be determined per the product standard
  • The resistance method must be planned for winding temperature
  • The worst-case operating mode must be determined
  • Mounting conditions must conform to the standard

Duration of Temperature Rise — IEC 60335

Depends on the time to reach steady state; typically half to one working day.

Temperature Rise — IEC 60335 Procedure

  1. 1Thermocouples are placed at the locations defined in the standard.
  2. 2The device is operated in the worst-case mode at the defined voltage.
  3. 3Temperatures are recorded until steady state is reached.
  4. 4Winding temperatures are calculated by the resistance method.
  5. 5A correction is made relative to ambient temperature.
  6. 6Results are compared with the limits.

Temperature Rise — IEC 60335 Acceptance Criteria

The acceptance criterion is the maximum temperature-rise values given in the product standard, per component and surface.

Evaluation of Results

Insulation-material class and accessible-surface-material limits are evaluated separately. The measurement is normalised to ambient temperature.

Temperature Rise — IEC 60335 Report

  • Standard applied
  • Supply and operating mode
  • Thermocouple locations
  • Measured temperatures and limits
  • Ambient-temperature correction

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • LVD 2014/35/EU
  • EcoDesign (for applicable products)

Electrical Safety — What Does This Testing Field Cover?

The section below describes the field that the Temperature Rise test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Electrical safety testing shows that a device poses no risk of electric shock, fire or injury to the user in normal use and under foreseeable fault conditions. This family is the test group most often requested when a product enters the market; almost every electrically operated product passes through this gate.

The logic of the field rests on a single assumption: FAULTS WILL HAPPEN. Insulation will age, a component will short, a cable will break, the user will misuse the device. Standards therefore test not only normal operation but also single fault conditions. The sentence "the device works correctly" is not evidence in this field; the evidence is that the device stays safe when it fails.

Assessment addresses three layers together. In the constructional layer, insulation distances (creepage and clearance), protective barriers, earthing continuity, enclosure strength and component selection are examined — this layer is largely a matter of inspection and measurement rather than testing. In the electrical layer, dielectric strength, leakage current, insulation resistance and behaviour under fault conditions are measured. In the thermal layer, temperature rise in normal and abnormal operation is monitored; an overheating component is both a fire risk and a risk of insulation breakdown.

Which standard applies is determined by WHAT THE PRODUCT IS, and that decision affects the entire outcome. Household appliances fall under the IEC 60335 series, information technology and audio/video products under IEC 62368-1, measurement and laboratory equipment under IEC 61010-1, and medical devices under IEC 60601-1. A report obtained under the wrong standard is not accepted in the file even if the measurements it contains are correct.

Component conformity is often overlooked in this field. The safety of the device rests on the conformity of the transformer, optocoupler, fuse, switch and power supply it uses. The list of critical components and the certification status of each is part of the technical file; a change of component reopens the safety assessment.

Method groups in this field

  • Constructional examination

    Insulation distances, barriers, earthing arrangement, accessibility and selection of critical components are examined. It comes before testing and many non-conformities are caught here.

  • Dielectric strength

    It is verified that the insulation withstands the defined voltage. It must not be confused with the routine test on the production line; the type test is more severe.

  • Leakage current and earthing

    The current that could reach the user is measured; the continuity and resistance of the protective earthing path are verified.

  • Heating tests

    Temperatures of components, windings and accessible surfaces are measured in normal and abnormal operation.

  • Fault condition tests

    Components are deliberately short-circuited or open-circuited; the appliance is expected not to cause a fire and not to make a hazardous part accessible.

  • Mechanical and enclosure tests

    Impact, drop, strain relief, IP protection and the safety of moving parts are assessed.

Commonly confused in this field

  • A CB certificate is not a CE declaration. CB is the output of a mutual recognition arrangement that eases national certification; the CE declaration is made by the manufacturer under its own responsibility.
  • A part of IEC 60335 is not sufficient on its own; it is applied together with Part 1.
  • IEC 60950-1 and IEC 60065 have been withdrawn. Old certificates based on these codes cannot be used in a current file.
  • Separate certification of the adapter does not cover the conformity of the device; the device is assessed as the system it forms together with its power supply.
  • A change of critical component (transformer, fuse, optocoupler supplier) is not a silent change; it requires the safety file to be reviewed.

Which decisions these results support

  • CE declaration under the Low Voltage Directive
  • IECEE CB certificate and entry into national certification schemes
  • Assessing the safety impact of design changes
  • Establishing and maintaining the critical component list
  • Responding to market surveillance requests

Related Tests

Frequently Asked Questions About Temperature Rise — IEC 60335

According to which standard is Temperature Rise made?

Temperature Rise is executed in scope IEC 60335-1, IEC 62368-1, IEC 61010-1, IEC 60598-1, IEC 60335, IEC 62368 and IEC 61010. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Temperature Rise apply to?

Mainly applied to Household and similar appliances, Information-technology equipment, Lighting fixtures, Power supplies and Motor-driven appliances. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Temperature Rise done?

The determining parameters are: Supply — A multiple of rated voltage defined in the standard (typically 106% or the worst-case value), Operating mode — The worst-case normal operating mode and Ambient temperature — Defined in the standard; measurements are corrected relative to this temperature. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Temperature Rise?

Thermocouple locations must be determined per the product standard, The resistance method must be planned for winding temperature and The worst-case operating mode must be determined. The number of samples is determined according to the product standard and the scope to be reported.

How long does Temperature Rise take?

Depends on the time to reach steady state; typically half to one working day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Temperature Rise result called "appropriate"?

The acceptance criterion is the maximum temperature-rise values given in the product standard, per component and surface.