IEC 60335IEC 62368IEC 61010
Electrical Safety laboratory work

What Is Overload — IEC 60335?

The overload test is a test in which current or mechanical load beyond the rated value is applied to the device or component, evaluating whether protective elements activate and no hazardous condition arises.

Purpose of Overload — IEC 60335

The purpose is to verify that, under overload, the device shuts down safely without creating a risk of burning, melting or electric shock.

Which Products Is Overload — IEC 60335 Applied To?

  • Motor-driven appliances
  • Power supplies and transformers
  • Protective devices and switchgear
  • Heating appliances
  • Electric hand tools

In Which Sectors Is Overload — IEC 60335 Used?

ElectricalElectronicsMachineryMedical Device

Standards Related to Overload — IEC 60335

  • IEC 60335Safety in home and similar electrical devices test
  • IEC 62368Security in audio, video and information technology devices test
  • IEC 61010Safety in measuring, control and laboratory devices test

Overload — IEC 60335 Conditions

Load level
A multiple of the rated value defined in the standard
Time
Until protection activates or steady state is reached
Monitoring
Temperature, current and protective-element behaviour
Repeats
A defined number of cycles in some standards

Equipment for Overload — IEC 60335

  • Programmable load rig
  • Current and voltage measurement
  • Temperature recording
  • Safety enclosure

Sample Requirements for Overload — IEC 60335

  • Rated values must be documented
  • The protective element's type and rating must be recorded
  • The specimen may become unusable after the test
  • Safety measures must be taken

Duration of Overload — IEC 60335

It depends on the number of scenarios; typically half to one business day.

Overload — IEC 60335 Procedure

  1. 1The rated value and overload level are determined.
  2. 2The specimen is operated at the defined overload.
  3. 3Current, temperature and protective behaviour are recorded.
  4. 4It continues until protection activates.
  5. 5Insulation and safety are checked after the test.

Overload — IEC 60335 Acceptance Criteria

The acceptance criterion is defined in the product standard: no emission of flame, no hazardous parts becoming accessible, and preservation of insulation.

Evaluation of Results

Protection's activation time and the peak temperature are evaluated. Non-conformity occurs if protection does not operate.

Overload — IEC 60335 Report

  • Standard applied
  • Rated value and overload level
  • Current and temperature records
  • Protective behaviour
  • Post-test safety checks

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • LVD 2014/35/EU
  • Machinery Directive

Electrical Safety — What Does This Testing Field Cover?

The section below describes the field that the Overload test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Electrical safety testing shows that a device poses no risk of electric shock, fire or injury to the user in normal use and under foreseeable fault conditions. This family is the test group most often requested when a product enters the market; almost every electrically operated product passes through this gate.

The logic of the field rests on a single assumption: FAULTS WILL HAPPEN. Insulation will age, a component will short, a cable will break, the user will misuse the device. Standards therefore test not only normal operation but also single fault conditions. The sentence "the device works correctly" is not evidence in this field; the evidence is that the device stays safe when it fails.

Assessment addresses three layers together. In the constructional layer, insulation distances (creepage and clearance), protective barriers, earthing continuity, enclosure strength and component selection are examined — this layer is largely a matter of inspection and measurement rather than testing. In the electrical layer, dielectric strength, leakage current, insulation resistance and behaviour under fault conditions are measured. In the thermal layer, temperature rise in normal and abnormal operation is monitored; an overheating component is both a fire risk and a risk of insulation breakdown.

Which standard applies is determined by WHAT THE PRODUCT IS, and that decision affects the entire outcome. Household appliances fall under the IEC 60335 series, information technology and audio/video products under IEC 62368-1, measurement and laboratory equipment under IEC 61010-1, and medical devices under IEC 60601-1. A report obtained under the wrong standard is not accepted in the file even if the measurements it contains are correct.

Component conformity is often overlooked in this field. The safety of the device rests on the conformity of the transformer, optocoupler, fuse, switch and power supply it uses. The list of critical components and the certification status of each is part of the technical file; a change of component reopens the safety assessment.

Method groups in this field

  • Constructional examination

    Insulation distances, barriers, earthing arrangement, accessibility and selection of critical components are examined. It comes before testing and many non-conformities are caught here.

  • Dielectric strength

    It is verified that the insulation withstands the defined voltage. It must not be confused with the routine test on the production line; the type test is more severe.

  • Leakage current and earthing

    The current that could reach the user is measured; the continuity and resistance of the protective earthing path are verified.

  • Heating tests

    Temperatures of components, windings and accessible surfaces are measured in normal and abnormal operation.

  • Fault condition tests

    Components are deliberately short-circuited or open-circuited; the appliance is expected not to cause a fire and not to make a hazardous part accessible.

  • Mechanical and enclosure tests

    Impact, drop, strain relief, IP protection and the safety of moving parts are assessed.

Commonly confused in this field

  • A CB certificate is not a CE declaration. CB is the output of a mutual recognition arrangement that eases national certification; the CE declaration is made by the manufacturer under its own responsibility.
  • A part of IEC 60335 is not sufficient on its own; it is applied together with Part 1.
  • IEC 60950-1 and IEC 60065 have been withdrawn. Old certificates based on these codes cannot be used in a current file.
  • Separate certification of the adapter does not cover the conformity of the device; the device is assessed as the system it forms together with its power supply.
  • A change of critical component (transformer, fuse, optocoupler supplier) is not a silent change; it requires the safety file to be reviewed.

Which decisions these results support

  • CE declaration under the Low Voltage Directive
  • IECEE CB certificate and entry into national certification schemes
  • Assessing the safety impact of design changes
  • Establishing and maintaining the critical component list
  • Responding to market surveillance requests

Related Tests

Frequently Asked Questions About Overload — IEC 60335

According to which standard is Overload made?

Overload is executed in scope IEC 60335-1, IEC 61010-1, IEC 60947 series, IEC 62368-1, IEC 60335, IEC 62368 and IEC 61010. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Overload apply to?

Mainly applied to Motor-driven appliances, Power supplies and transformers, Protective devices and switchgear, Heating appliances and Electric hand tools. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Overload done?

The determining parameters are: Load level — A multiple of the rated value defined in the standard, Time — Until protection activates or steady state is reached and Monitoring — Temperature, current and protective-element behaviour. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Overload?

Rated values must be documented, The protective element's type and rating must be recorded and The specimen may become unusable after the test. The number of samples is determined according to the product standard and the scope to be reported.

How long does Overload take?

It depends on the number of scenarios; typically half to one business day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Overload result called "appropriate"?

The acceptance criterion is defined in the product standard: no emission of flame, no hazardous parts becoming accessible, and preservation of insulation.