Loading

Textile Testing · Chemical and compliance

Flammability

RTCA DO-160EUROCAE ED-14ISO 7137
Tekstil Testleri laboratory work

What Is Flammability?

This test is carried out to evaluate the ignition, burning rate and self-extinguishing behavior of equipment materials within the scope of Chapter 26 (“Fire, Flammability”) of the RTCA DO-160 “Environmental Conditions and Test Procedures for Airborne Equipment” standard. DO-160 is the exact same text as EUROCAE ED-14 and is recognized by ISO as ISO 7137.

Purpose of Flammability

The aim is to certify that aviation equipment meets the requirements regarding the evaluation of ignition, burning rate and self-extinguishing behavior of equipment materials in flight and ground conditions and to complete equipment qualification.

Which Products Is Flammability Applied To?

  • Avionics units and displays
  • In-flight electronic equipment
  • Communication and navigation devices
  • Cabin and cargo compartment equipment
  • Sensors and actuators

In Which Sectors Is Flammability Used?

TextilesLeatherFootwearRetail

Standards Related to Flammability

  • RTCA DO-160Environmental conditions and test methods in aviation equipment test
  • EUROCAE ED-14
  • ISO 7137

Flammability Conditions

Method
Vertical or horizontal burning test; by category
Flame application time
Defined in standard
Assessment
Burning time, burning length and flaming drop
Specimen
Material sample or actual part

Equipment for Flammability

  • Flammability test cabin
  • burner and timer
  • Numune tutucu
  • ventilation pattern

Sample Requirements for Flammability

  • Malzeme listesi belgelenmeli
  • Sample thickness should represent the most unfavorable use
  • Conditioning must be applied

Duration of Flammability

It is short per sample; one set is typically completed in one business day.

Flammability Procedure

  1. 1The method and flame duration are determined.
  2. 2The sample is placed in the holder.
  3. 3Flame defined time is applied.
  4. 4Burning time and length are measured.
  5. 5Flaming drop behavior is observed.

Flammability Acceptance Criteria

Acceptance criteria are maximum burning time, maximum burning length and flaming drop limits defined in the standard.

Evaluation of Results

Aviation flammability requirements for cabin interior materials also apply.

Flammability Report

  • Applicable standard, revision and Part 26
  • Selected equipment category and justification
  • Applied conditions and measurement results
  • Function monitoring method and observations
  • Environmental Qualification Form (DO-160 Environmental Qualification Form) entry

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Aviation equipment qualification requirements
  • EASA/FAA certification principles

Tekstil Testleri — What Does This Testing Field Cover?

The section below describes the field that the Flammability test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Textile testing answers two questions separately: does the fabric hold up physically over its service life, and does it carry any substance restricted for human health? These two axes require different laboratory infrastructure and different decision mechanisms.

On the physical side, breaking and tear strength, abrasion resistance, pilling, dimensional change, colour fastness and water and oil repellency are measured. Most of these tests depend on the USE SCENARIO: Martindale abrasion cycles are decisive for an upholstery fabric, while dimensional change in washing and colour fastness come to the fore for a shirting fabric. The same fabric goes through a different test set for a different use.

Colour fastness is a body of work of its own in this field and is not a single test. The fastness of the same fabric to light, washing, rubbing, perspiration, saliva, chlorinated water and ironing is measured separately; each represents a different moment of use. Results are rated from 1 to 5 on the grey scale and the specification gives a separate minimum rating for each agent.

On the chemical side, aromatic amines released from azo dyes, formaldehyde, heavy metals, phthalates, short-chain chlorinated paraffins, alkylphenols and PFAS compounds are screened. These items come from REACH restrictions, brand restricted substance lists (RSL) and voluntary schemes such as OEKO-TEX. Brand lists are often stricter than legislation; the target customer is decisive.

There is NO CE marking on consumer textiles. The obligation has three legs: fibre composition and care labelling, compliance with chemical restrictions, and general product safety. Textiles claiming a protective function (workwear, flame-resistant clothing, high-visibility clothing) fall under personal protective equipment legislation, where CE is mandatory — this distinction is commercially critical.

Verifying the label declaration is the most routine work in the field. Quantitative fibre analysis confirms the blend ratio stated on the label; tolerance ranges are defined in legislation. An incorrect fibre declaration both misleads the consumer and affects customs classification.

Sustainability claims have added a new body of work to the field in recent years: verification of recycled content (GRS, RCS), organic content (GOTS), restriction of harmful chemicals and water/energy footprint declarations. These claims now require auditable evidence.

Method groups in this field

  • Strength and durability

    Strip and grab breaking strength, tearing by the Elmendorf and tongue methods, seam strength, bursting strength.

  • Abrasion and surface

    Martindale and rotary platform abrasion, pilling and fuzzing, fabric mass and thread density measurements.

  • Dimensional stability

    Dimensional change in washing and drying, wrinkling behaviour, appearance after ironing.

  • Colour fastness

    Fastness to light (xenon), washing, rubbing, perspiration, saliva, water and chlorinated water; rating on the grey scale.

  • Functional properties

    Water repellency (spray test), oil repellency, waterproofness, air permeability, effectiveness of antibacterial finishes, UV protection factor.

  • Chemical analyses

    Aromatic amines from azo dyes, formaldehyde, pH, heavy metals, phthalates, chlorinated phenols, PFAS and alkylphenols.

Commonly confused in this field

  • A brand restricted substance list (RSL) may be stricter than legislation; REACH compliance does not mean compliance with the customer specification.
  • Textiles claiming a protective function fall under PPE legislation and require CE; an ordinary textile test report does not satisfy that file.
  • Colour fastness is not a single number; a rating cannot be interpreted without stating which agent it relates to.
  • A result obtained for a fabric does not cover the whole garment made from it; lining, sewing thread, print and trims are assessed separately.
  • Performance claims after washing are valid together with the stated number of wash cycles; the word "permanent" on its own is not verifiable.

Which decisions these results support

  • Compliance with the brand restricted substance list (RSL)
  • Verification of label declarations: fibre composition and care instructions
  • Determining the performance class of upholstery and technical textiles
  • Pre-import shipment inspection and lot acceptance
  • Supporting sustainability and recycled content claims

Related Tests

Frequently Asked Questions About Flammability

How is the equipment category determined?

The category is selected based on the equipment's mounting location on the aircraft (pressurized/non-pressurized, heated/unheated area) and aircraft type. Category selection directly determines the test conditions and is declared in the qualification form.

Is there any difference between DO-160 and ED-14?

No. RTCA DO-160 and EUROCAE ED-14 are exactly the same text; the two are considered equivalent.

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy