What Is Fluids Susceptibility — RTCA DO-160?
This test is carried out within the scope of Chapter 11 (“Fluids Susceptibility”) of the RTCA DO-160 “Environmental Conditions and Test Procedures for Airborne Equipment” standard to evaluate the resistance of the equipment to fuel, oil, hydraulic fluid and cleaning agents used in the aircraft. DO-160 is the exact same text as EUROCAE ED-14 and is recognized by ISO as ISO 7137.
Purpose of Fluids Susceptibility — RTCA DO-160
The aim is to certify that the aviation equipment meets the requirements regarding the evaluation of the equipment's resistance to fuel, oil, hydraulic fluids and cleaning agents used in the aircraft under flight and ground conditions and to complete the equipment qualification.
Which Products Is Fluids Susceptibility — RTCA DO-160 Applied To?
- Avionics units and displays
- In-flight electronic equipment
- Communication and navigation devices
- Cabin and cargo compartment equipment
- Sensors and actuators
In Which Sectors Is Fluids Susceptibility — RTCA DO-160 Used?
Standards Related to Fluids Susceptibility — RTCA DO-160
- RTCA DO-160Environmental conditions and test methods in aviation equipment test
Fluids Susceptibility — RTCA DO-160 Conditions
- Kategoriler
- F (spraying), S (immersion)
- liquids
- Fuel, hydraulic fluid, engine oil, defroster, cleaning agents
- Temperature
- Defined in the standard; often elevated temperature
- Time
- Defined by liquid and category
Equipment for Fluids Susceptibility — RTCA DO-160
- Liquid spraying and immersion arrangement
- Temperature-controlled oven
- Chemical resistant test containers
- Function monitoring
Sample Requirements for Fluids Susceptibility — RTCA DO-160
- A list of liquids to be exposed should be determined.
- Material compatibility should be evaluated in advance
- The sample may be unusable after
Duration of Fluids Susceptibility — RTCA DO-160
It depends on the number of liquids; typically a few days.
Fluids Susceptibility — RTCA DO-160 Procedure
- 1The liquid list and category are determined.
- 2The sample is exposed to the liquid by spraying or immersion.
- 3It is kept at a defined temperature and time.
- 4Surface and seal deterioration are examined.
- 5The function is checked.
Fluids Susceptibility — RTCA DO-160 Acceptance Criteria
The acceptance criterion is that material degradation does not affect function and safety.
Evaluation of Results
Deterioration of seals, coatings and labels is particularly evaluated.
Fluids Susceptibility — RTCA DO-160 Report
- Applicable standard, revision and Part 11
- Selected equipment category and justification
- Applied conditions and measurement results
- Function monitoring method and observations
- Environmental Qualification Form (DO-160 Environmental Qualification Form) entry
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Aviation equipment qualification requirements
- EASA/FAA certification principles
Aerospace Testing — What Does This Testing Field Cover?
The section below describes the field that the Fluids Susceptibility test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Aerospace testing shows that equipment keeps working in the flight environment and provides evidence for the airworthiness file. In this family the acceptable probability of failure is several orders of magnitude lower than in other sectors; this directly determines the scope of testing and the certification burden.
The most distinctive feature of the field is TRACEABILITY. Which melt an aircraft part came from, in which heat treatment furnace and with which cycle it was processed, which operator made the weld and which inspector approved it are all recorded. The test report is one link in this chain; if the chain is broken, the report carries no value on its own.
Environmental qualification runs through RTCA DO-160, with categories selected according to the equipment's MOUNTING LOCATION in the aircraft. A device mounted on the cockpit panel and one mounted inside the wing pass the same section under different categories. When reading a DO-160 report it is therefore essential to know which sections were applied at which categories.
On the software and complex hardware side the approach changes entirely: the evidence is not testing but PROCESS ASSURANCE. DO-178C for software and DO-254 for complex electronic hardware define how the development process is to be run and which evidence is to be produced. Every step, from requirement to code, from testing of the code to coverage analysis, must be traceable. Testing software does not make it certifiable; the process record does.
A separate body of work applies on the material and special process side. AWS D17.1 is used for welding, SAE AMS 2750 for pyrometry in heat treatment and NAS 410 for non-destructive testing personnel. For special processes (heat treatment, coating, welding, NDT, bonding) NADCAP accreditation is effectively mandatory in the supply chain; without NADCAP it is not possible to sell parts to many OEMs.
On the quality system side the AS/EN 9100 series is used: 9100 for manufacturers, 9110 for maintenance organisations and 9120 for distributors. Without these certificates it is practically impossible to enter the aerospace supply chain, and audits are markedly more detailed than in other sectors.
Counterfeit part risk is a subject peculiar to the field. Separate standards and verification methods (visual inspection, X-ray, decapsulation and internal structure examination, XRF) are used to detect counterfeit or reworked parts in the electronic component supply chain.
Space applications add further layers: outgassing in vacuum, radiation tolerance, long-duration thermal vacuum cycling and assessment of single event effects.
Method groups in this field
Environmental qualification
RTCA DO-160 sections: temperature and altitude, vibration, shock, humidity, sand and dust, fungus, salt fog, fluid susceptibility, icing, lightning.
Electromagnetic
The EMC sections of DO-160; MIL-STD-461 and MIL-STD-704 power characteristics on military platforms.
Software and hardware assurance
DO-178C software life cycle and DO-254 hardware design assurance evidence; requirement traceability and coverage analysis.
Materials and welding
Welding qualification under AWS D17.1, mechanical testing of materials, metallography and non-destructive examination.
Special process control
SAE AMS 2750 pyrometry, coating and heat treatment process verification, preparation for NADCAP audits.
Space environment
Thermal vacuum cycling, outgassing, radiation tolerance and acoustic/vibration qualification.
Commonly confused in this field
- There is no such document as a "DO-160 certificate"; DO-160 is a test specification and its output is a qualification report.
- The selection of sections and categories comes from the customer's equipment specification; the laboratory cannot make that selection on its own.
- DO-178C and DO-254 cannot be satisfied by testing; the evidence is the traceability of the development process.
- An AS9100 certificate is not a product approval; it is a quality system certificate and part approval runs separately.
- For special processes, work carried out without NADCAP is not accepted in the supply chain even when it is technically correct.
- MIL-STD-810 and DO-160 are often confused: one is a military and the other a civil aviation specification, and their profiles differ.
Which decisions these results support
- Airworthiness and TSO/ETSO files
- Entry into the aerospace supply chain and supplier approval
- Special process approval and NADCAP preparation
- Determining the impact of a design change on qualification
- Managing counterfeit part risk and component verification
Related Tests
Frequently Asked Questions About Fluids Susceptibility — RTCA DO-160
How is the equipment category determined?
The category is selected based on the equipment's mounting location on the aircraft (pressurized/non-pressurized, heated/unheated area) and aircraft type. Category selection directly determines the test conditions and is declared in the qualification form.
Is there any difference between DO-160 and ED-14?
No. RTCA DO-160 and EUROCAE ED-14 are exactly the same text; the two are considered equivalent.