What Is Resonance Dwell?
The resonance dwell test is one in which the sample is vibrated for a defined duration at the critical frequencies identified by resonance search. It constitutes the worst-case loading condition.
Purpose of Resonance Dwell
The purpose is to verify that the sample withstands long-duration vibration fatigue at its most demanding frequency.
Which Products Is Resonance Dwell Applied To?
- Electronic boards and connections
- Automotive and aerospace components
- Piping and support elements
In Which Sectors Is Resonance Dwell Used?
Standards Related to Resonance Dwell
- IEC 60068-2-6sine vibration test test
- MIL-STD-810 Method 514
- IEC 60068series of environmental testing methods test
- MIL-STD-810environmental engineering assessments and laboratory tests test
- RTCA DO-160Environmental conditions and test methods in aviation equipment test
- SAEautomotive and aerospace engineering standards test
- ISO 16750Environmental conditions in vehicle electrical/electronic equipment test
- UN 38.3Transport safety tests on lithium batteries test
Resonance Dwell Conditions
- Frequency
- Critical frequency(s) determined by resonance search
- Genlik
- Acceleration level defined in the specification
- Time
- Defined dwell time or number of cycles for each resonance
- Frekans takibi
- If the resonance shifts, it is followed or held constant; determines specification
Equipment for Resonance Dwell
- Electrodynamic shaker
- Vibration control system (with frequency tracking)
- Accelerometers
- Function monitoring
Sample Requirements for Resonance Dwell
- Critical frequencies must be identified in advance
- Function or resistance monitoring must be set up
- The fixture must be checked
Duration of Resonance Dwell
Depends on the number of resonances and dwell time; typically one to two working days.
Resonance Dwell Procedure
- 1Resonance search results are obtained.
- 2The sample is vibrated at the critical frequency.
- 3Sustained for the defined duration.
- 4Resonance shift is monitored and tracked if necessary.
- 5Repeated for each critical frequency.
- 6Function and visual inspection are carried out.
Resonance Dwell Acceptance Criteria
The acceptance criterion is defined in the specification: no cracking, loosening or loss of function.
Evaluation of Results
A shift in resonance during dwell indicates the onset of structural degradation and is recorded.
Resonance Dwell Report
- Standard applied
- Critical frequencies and amplitudes
- Dwell times
- Resonance shift record
- Function and inspection results
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Aerospace and automotive component specifications
Vibration and Shock — What Does This Testing Field Cover?
The section below describes the field that the Resonance Dwell test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Vibration and shock testing shows whether a product withstands mechanical dynamic loads. The two phenomena are distinct: vibration is a continuous and repeated loading, while shock is a single instantaneous impact at high acceleration. They produce different failure modes and are required separately.
The failure produced by vibration is FATIGUE: a solder joint cracks, a cable sheath abrades, a screw loosens, a connector loses contact. The failure produced by shock is FRACTURE: a brittle component shatters, a bracket breaks, a board comes out of its holder. Testing a product under vibration therefore does not show that it also withstands shock.
Vibration is applied in three forms, each giving different information. Sine vibration sweeps at a single frequency; it is used to find the resonant frequencies of the product and is very valuable at the design stage. Random vibration represents the broadband nature of the real environment and is preferred as evidence of durability. Sine-on-random and random-on-random profiles simulate together the broadband noise superimposed on dominant frequencies from engines and rotors — this is necessary in helicopter and turboprop applications.
RESONANCE is the concept at the centre of the field. Every structure has its own natural frequencies; as the excitation frequency approaches one of them the amplitude grows and the product is exposed to an acceleration many times the input level. A resonance search is therefore carried out before the test, and a design change often takes the form of shifting the resonance rather than lowering the level.
In this family the FIXTURE is part of the result, and this is the most frequently overlooked point. How the specimen is attached to the shaker directly changes the energy transmitted and the resonance behaviour. A poorly designed fixture brings its own resonances into play and imposes a load the product would not otherwise see, or conversely damps the real load and protects the product. Results obtained with different fixtures cannot be compared.
The choice of measurement point also determines the result. The control accelerometer is placed on the fixture and monitoring accelerometers at critical points of the product; the report must document these positions. Accelerations measured at different points in the same test can differ markedly.
Profiles are divided by application area: transport vibration (packaging and shipping), vehicle vibration (by mounting location), rail (EN 61373 categories), aviation (DO-160 sections), military (MIL-STD-810 methods) and battery transport (UN 38.3 T3). The same product passes through different profiles under different programmes.
Method groups in this field
Sine vibration
Determining resonances by frequency sweep and withstand at defined frequencies; the most informative test at the design stage.
Random vibration
Durability with a broadband power spectral density profile; the approach that best represents the real environment.
Combined profiles
Sine-on-random and random-on-random; for dominant frequencies arising from rotating machinery.
Classical shock
Defined acceleration and duration with half-sine, sawtooth and trapezoidal pulse shapes.
Free fall and toppling
Realistic drop scenarios arising from handling; decisive for portable products.
Resonance search and monitoring
Detection of structural change (cracking, loosening) by sweeps before and after the test.
Commonly confused in this field
- Shock and vibration are not the same test; one produces fracture and the other fatigue, and they are required separately.
- A report that does not document the fixture cannot be compared; a fixture can bring its own resonance into play.
- Levels come from the product standard or the programme specification; the standard does not define a single universal level.
- Without a resonance sweep before and after the test, structural damage can go unnoticed; the product may appear to work while being cracked internally.
- The position of the measurement point must be reported; accelerations measured at different points in the same test differ markedly.
- If the product is not operated during the test, intermittent loss of contact remains invisible.
Which decisions these results support
- Verification of transport and in-use durability
- Transport and vehicle vibration conformity for batteries
- Rail, aviation and defence qualification files
- Root cause analysis of solder, connector and joint failures
- The decision to shift a resonance through a design change
Related Tests
Frequently Asked Questions About Resonance Dwell
According to which standard is Resonance Dwell made?
Resonance Dwell is executed in scope IEC 60068-2-6 and MIL-STD-810 Method 514. The limit values and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.
Which products does Resonance Dwell apply to?
Mainly applied to Electronic boards and connections, Automotive and aerospace components and Piping and support elements. Whether your product is included in the scope is determined by examining its technical specifications and intended use.
Under what conditions is Resonance Dwell done?
The determining parameters are: Frequency — Critical frequency(s) determined by resonance search, Genlik — Acceleration level defined in the specification and Time — Defined dwell time or number of cycles for each resonance. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.
What kind of sample is needed for Resonance Dwell?
Critical frequencies must be identified in advance, Function or resistance monitoring must be set up and The fixture must be checked. The number of samples is determined according to the product standard and the scope to be reported.
How long does Resonance Dwell take?
Depends on the number of resonances and dwell time; typically one to two working days. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.
What is the Resonance Dwell result called "appropriate"?
The acceptance criterion is defined in the specification: no cracking, loosening or loss of function.