What Is Density?
Density determination is the measurement in which the ratio of the mass of the sample to its volume is determined by immersion (Archimedes), pycnometer or flotation (gradient tube) methods.
Purpose of Density
The purpose is to perform identity verification, fill rate control and porosity assessment by determining the density of the material.
Which Products Is Density Applied To?
- Plastic and rubber parts
- Composites with filler additives
- Coating and painting (ISO 2811)
- Metal and ceramic samples
In Which Sectors Is Density Used?
Standards Related to Density
- ISO 1183-1
- ISO 1183-2
- ASTM D792
- ISO 2811-1
Density Conditions
- Method
- Immersion (A), pycnometer (B), or density gradient tube
- Temperature
- Defined in the standard; usually 23 °C ± 2 °C
- immersion liquid
- Distilled water or liquid that does not interact with the sample
- Number of specimens
- Defined in the standard; The mean and distribution are given
Equipment for Density
- Analytical balance and immersion plate
- Pycnometer set
- density gradient tube
- Temperature-controlled bath
Sample Requirements for Density
- There should be no air bubbles on the sample surface.
- If the sample is porous, the method should be chosen accordingly
- Sample temperature must be stabilized
- The sample must not swell in the immersion liquid
Duration of Density
Typically 1 day.
Density Procedure
- 1The sample is conditioned and weighed in air.
- 2It is weighed (or measured with a pycnometer) in the immersion liquid.
- 3Liquid temperature and density are recorded.
- 4Density is calculated.
- 5Iterated and averaged for a defined number of samples.
Density Acceptance Criteria
The acceptance criterion is the density range given in the material standard.
Evaluation of Results
The immersion method gives incorrect results in open-pore samples; If porosity is present, method selection and sample coating requirement should be evaluated against the standard.
Density Report
- Standard and method applied
- Temperature and immersion liquid
- Weighing values
- Calculated density and distribution
- Assessment against the material standard
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Material product standards
Kozmetik Testleri — What Does This Testing Field Cover?
The section below describes the field that the Density test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Cosmetics testing shows that a product stays microbiologically safe throughout its use, delivers the performance it claims and contains no restricted substances. There is NO PRODUCT APPROVAL in this family: no authority approves a cosmetic product; responsibility rests entirely with the manufacturer and with the responsible person established in the EU.
This responsibility model shapes how the field works. Before the product is placed on the market a product information file (PIF) is prepared, a safety assessment (CPSR) is carried out and notification is completed. Inspection comes afterwards and asks for the file; if the file is incomplete the product is withdrawn from the market. Test reports form the evidence base of that file.
On the microbiological side there are two different questions and each is answered by a separate test. The CURRENT microbiological quality of the product is measured by enumeration and testing for specified microorganisms. The EFFECTIVENESS of the preservative system is examined by deliberately inoculating the product with microorganisms (challenge test): can the product resist repeated contamination throughout its use? A jar of cream is touched by a finger at every use; the preservative system must cope with that.
On the performance side, claim substantiation studies are carried out. For sunscreens, determination of SPF and UVA protection and measurement of water resistance are mandatory and are the basis of the value declared on the label. Evidence is also produced by in vivo or in vitro methods for claims such as moisturisation, appearance of wrinkles, hair care and colour retention.
On the chemical side, banned and restricted substances are screened: heavy metals, prohibited colorants, preservative concentrations, UV filter levels and contaminants such as nitrosamines. Products containing nanomaterials carry a separate notification obligation.
The BAN ON ANIMAL TESTING is the most defining constraint of the field. Animal testing cannot be carried out on finished products or ingredients, and a product tested on animals cannot be placed on the market. Alternative in vitro methods (reconstructed human skin models, cell culture based tests) are therefore at the centre of the field, and toxicological assessment rests largely on existing data, read-across approaches and in vitro results.
Stability and packaging compatibility studies determine shelf life and the period after opening (PAO). The interaction of the product with its packaging is also assessed: an active substance may migrate into the packaging, and substances that should not be present may pass from the packaging into the product.
On the process side, good manufacturing practice is demonstrated through ISO 22716; this is separate from product testing but a mandatory part of the file.
Method groups in this field
Microbiological quality
Enumeration of aerobic mesophilic bacteria, yeasts and moulds; testing for Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and E. coli.
Preservative efficacy
Resistance of the preservative system to repeated contamination by challenge test (ISO 11930).
Sun protection
In vivo SPF determination, in vitro UVA protection determination, water resistance and critical wavelength measurements.
Chemical analysis
Heavy metals, banned and restricted substances, quantification of preservatives and UV filters, contaminant screening.
Safety assessment
In vitro irritation and sensitisation methods, toxicological risk assessment, exposure calculations.
Stability and compatibility
Real-time and accelerated stability, packaging compatibility, PAO determination, sensory and physicochemical monitoring.
Commonly confused in this field
- There is NO CE marking on cosmetics; conformity is demonstrated through the PIF, the safety assessment and notification.
- The responsible person must be established in the EU; unless the exporter arranges this, the product cannot be placed on the market.
- Microbiological quality and preservative efficacy are different tests; a product that comes out clean may still have a weak preservative system.
- The animal testing ban covers ingredients too; animal test data generated for another market creates a problem of use.
- An SPF claim must be supported by measurement; a formulation change requires a new measurement.
- A change of packaging may require the stability and compatibility studies to be repeated.
Which decisions these results support
- The product information file and the safety assessment
- Verification of the preservative system design
- Substantiation of SPF and efficacy claims
- Determining shelf life and the period after opening
- Compliance with destination market restrictions for export
Related Tests
Frequently Asked Questions About Density
According to which standard is Density made?
Density is executed in scope ISO 1183-1, ISO 1183-2, ASTM D792 and ISO 2811-1. The limit values and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.
Which products does Density apply to?
Mainly applied to Plastic and rubber parts, Composites with filler additives, Coating and painting (ISO 2811) and Metal and ceramic samples. Whether your product is included in the scope is determined by examining its technical specifications and intended use.
Under what conditions is Density done?
The determining parameters are: Method — Immersion (A), pycnometer (B), or density gradient tube, Temperature — Defined in the standard; usually 23 °C ± 2 °C and immersion liquid — Distilled water or liquid that does not interact with the sample. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.
What kind of sample is needed for Density?
There should be no air bubbles on the sample surface., If the sample is porous, the method should be chosen accordingly and Sample temperature must be stabilized. The number of samples is determined according to the product standard and the scope to be reported.
How long does Density take?
Typically 1 day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.
What is the Density result called "appropriate"?
The acceptance criterion is the density range given in the material standard.