What Is Chemical Composition?
Chemical composition analysis determines which elements make up the metal and in what proportions. The most common method is spark optical emission spectrometry (OES): a spark generated on the sample surface excites the elements, each element emits light at its own characteristic wavelength, and the intensity is proportional to concentration.
Purpose of Chemical Composition
The purpose is to verify whether the material truly conforms to its declared alloy grade. Incorrect material use is the most frequent cause of consequences such as weld cracking, unexpected corrosion, and loss of strength.
Which Products Is Chemical Composition Applied To?
- Steel and stainless steel products
- Aluminium and copper alloys
- Cast parts
- Weld filler materials
- Incoming material acceptance inspection
In Which Sectors Is Chemical Composition Used?
Standards Related to Chemical Composition
- ASTM E415 (spark AES in carbon and low-alloy steel)
- ASTM E1251 (spark AES in aluminium and its alloys)
- EN 10204 (inspection documents for metallic products)
- Laboratory method validation under ISO 17025
Chemical Composition Conditions
- Method
- Spark OES; carbon/sulfur by ICP-OES or combustion method if necessary
- Surface
- The measuring surface is ground; Removes oxide, dye and oil
- Calibration
- With certified reference materials in accordance with the material matrix
- Repeats
- Multiple measurements and averages at different points
Equipment for Chemical Composition
- Spark optical emission spectrometer
- Carbon/sulfur analyser (combustion method)
- Sample surface preparation grinding setup
- Certified reference material set
- Argon supply system
Sample Requirements for Chemical Composition
- The sample must be taken so as to represent the batch or production run.
- Sample description, material type, and production direction if any, must be stated.
- The standard to be applied and any customer specification must be provided together with the sample.
- The test may be destructive; the required number of samples must be confirmed in advance.
- Surfaces that will be tested must be protected during transport.
Duration of Chemical Composition
Analysis of a sample, including surface preparation, is generally completed within the same working day.
Chemical Composition Procedure
- 1The sample surface is ground and cleaned.
- 2The instrument is verified with the appropriate matrix programme and reference material.
- 3The sample is placed on the measurement stand.
- 4Spark measurements are taken at different points.
- 5Carbon and sulfur are additionally measured by the combustion method if required.
- 6The results are averaged.
- 7Composition is compared against the range in the material standard.
Chemical Composition Acceptance Criteria
The method standard defines how the test is performed, not what the result must be. The acceptance limit comes from the material or product standard, the customer specification, or the relevant regulation; this page therefore does not give a numerical limit.
Evaluation of Results
The result is compared against the element ranges in the material's declared standard. Even a single element outside the range changes the material grade; in that case which grade the material actually conforms to is separately assessed.
Chemical Composition Report
- Sample description, material/product information, and batch number if any
- Sample preparation method and conditioning conditions
- Standard and test conditions applied
- Instrument used and calibration status
- Measurement results and units
- Measurement uncertainty (if requested)
- A statement that the result applies only to the specimen submitted for testing
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Harmonised standards applied according to the product family
- EU 765/2008 (market surveillance and accreditation framework)
- Relevant product regulations and customer specifications
Metal and Metallurgy Testing — What Does This Testing Field Cover?
The section below describes the field that the Chemical Composition test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Metal and metallurgical testing determines the load a metal or a welded joint can carry, how it fails and what its internal structure looks like. The output of this family is often not about the product itself but about the identity of the MATERIAL: is the steel really of the declared grade, does the weld seam deliver the strength the design assumes, does the casting contain an unacceptable internal defect?
The practical importance of the field comes from the fact that a metal part rarely fails gradually. A plastic part deforms, ages, cracks and usually gives warning. A weld seam or a fastener, by contrast, often breaks without warning — especially where fatigue and brittle fracture are involved. That is why in fields such as pressure equipment, lifting gear, structural steel and pipelines, material testing is a requirement of REGULATION rather than of design.
The family brings together three groups of methods, and each answers a different question. Mechanical tests quantify how the material behaves under load. Non-destructive examination looks for defects without damaging the part. Metallography and chemical analysis explain why the material behaves the way it does — through grain structure, phase distribution, inclusion content and alloy composition.
The acceptance criterion for these tests almost never comes from the test standard, and this is the key to understanding the field. The test standard says how the measurement is to be made; the acceptable values come from the product standard, the material grade or the fabrication code. ISO 6892-1 tells you how to run a tensile test; EN 10025 tells you what yield strength that steel must deliver. When reading a report, the product standard it was assessed against is essential.
Sampling is an inseparable part of the result in this field. Two specimens taken from the same heat may give different values depending on the direction and location they were taken from; in rolled products, specimens parallel and perpendicular to the rolling direction produce different results. Product standards therefore also govern sampling location and orientation, and the report must document this.
Method groups in this field
Mechanical tests
Tensile, compression, bending, notch impact (Charpy), hardness (Brinell, Vickers, Rockwell), fatigue, creep and fracture toughness. These give the behaviour of the material under load in numerical form.
Non-destructive examination
Radiography, ultrasonic examination, penetrant, magnetic particle and visual examination. It looks for surface and internal defects without damaging the part and is an indispensable step in welded fabrication.
Metallography
Specimen preparation, etching and microscopic examination. Grain size, phase distribution, inclusion content, case depth and the weld heat-affected zone are assessed.
Chemical analysis
Alloy composition is verified by optical emission spectrometry and wet chemistry; confirmation of the material grade runs through this step.
Corrosion behaviour
Salt spray, pitting and crevice corrosion and intergranular corrosion tests. In stainless steels these can indicate the quality of the heat treatment.
Commonly confused in this field
- A material certificate (such as EN 10204 3.1) is not a test report; it is the manufacturer's declaration. In critical applications independent verification is carried out, and the two must not be confused.
- ASTM and ISO tensile tests measure the same quantities but use different specimen geometries; the results are not treated as directly equivalent, and whichever the specification calls for is the one applied.
- Conversion tables between hardness and strength are APPROXIMATE. Calculating yield strength from hardness is not sufficient evidence for material acceptance.
- In non-destructive examination, "no defect found" does not mean there is no defect; defects below the detection limit of the method may be present. The report must state the method applied and the sensitivity level.
- A weld seam passing does not show that the welder or the procedure is qualified; these are separate processes.
Which decisions these results support
- Verifying the material certificate and accepting incoming material
- Approving welded fabrication; welder and procedure qualification
- Manufacturing control of pressure equipment and structural components
- Failure analysis and determining the root cause of field damage
- Verifying heat treatment and surface treatment processes
Related Tests
Frequently Asked Questions About Chemical Composition
Is this the same as PMI?
No. PMI is a quick field verification performed with a portable instrument and generally cannot read carbon. Laboratory OES analysis gives the full composition with lower uncertainty.
Why is carbon measured separately?
Light elements such as carbon, sulfur and nitrogen may not be reliably measured by spark OES. Separate combustion- or fusion-based analysers are used for these elements.