What Is Irritation?
The irritation test evaluates whether substances released from the device cause redness, oedema or tissue damage at the tissue in contact. ISO 10993-23 is applied for skin irritation, and ISO 10993-10 and related sections for mucosal and intracutaneous reactivity.
Purpose of Irritation
The purpose is to determine whether the material shows a local irritant effect on the tissue it contacts.
Which Products Is Irritation Applied To?
- Skin-contacting devices
- Mucosa-contacting products (catheters, probes, dental products)
- Wound dressings
- Injection and infusion sets
- Surgical drapes and gloves
In Which Sectors Is Irritation Used?
Standards Related to Irritation
- ISO 10993-23irritation assessment test
- ISO 10993-10skin sensitivity assessment test
- ISO 10993-12
- OECD TG 439
- OECD TG 492
- ISO 11607end product sterile barrier packaging test
Irritation Conditions
- Method
- Reconstructed human epidermis (RhE) model or intracutaneous reactivity; according to contact type
- Extraction
- Separate extracts with polar and non-polar solvents
- Assessment
- Percentage tissue viability, or erythema/oedema scoring
Equipment for Irritation
- RhE tissue model and incubator
- Microplate reader
- Biosafety cabinet
- Extraction rig
- Scoring and imaging equipment
Sample Requirements for Irritation
- The specimen must represent the final, sterilised product
- Not raw material — the product that has gone through all manufacturing and sterilisation processes is submitted
- The specimen quantity is determined according to the surface-area/extraction ratio prescribed by the standard
- The device's type and duration of body contact must be stated
- The sterilisation method and, if applicable, residue information must be shared
Duration of Irritation
1–2 weeks for in-vitro methods; the duration extends if an animal model is applied.
Irritation Procedure
- 1The appropriate method is selected and justified according to the contact type.
- 2The specimen is extracted with polar and non-polar solvents.
- 3The RhE model or the relevant test system is prepared.
- 4The extract is applied and incubated for the defined duration.
- 5Positive and negative controls are run in parallel.
- 6Tissue viability is measured, or reactions are scored.
- 7The result is assessed and reported.
Irritation Acceptance Criteria
The common acceptance criterion in RhE-based methods is that tissue viability does not fall below 50% of the negative control. In scoring-based methods, erythema and oedema scores must not exceed the threshold defined in the standard.
Evaluation of Results
The controls showing the expected behaviour is essential for test validity. For borderline results, extraction conditions and specimen preparation are reviewed again.
Irritation Report
- Applied standard and revision
- Specimen description, batch number and sterilisation method
- Extraction conditions (solvent, temperature, duration, ratio)
- Positive and negative control results
- Test results and grading
- Assessment and conclusion
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- MDR (EU) 2017/745
- ISO 10993-1 biological evaluation plan
Medikal Cihaz Testleri — What Does This Testing Field Cover?
The section below describes the field that the Irritation test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Medical device testing shows that a device is safe for the patient and the user and maintains its intended performance. In this family safety is not only about avoiding harm; a device failing to perform its expected function is also treated as a risk. A monitor missing an alarm or a pump delivering the wrong dose is directly a patient safety event.
At the centre of the field is RISK MANAGEMENT, and this is what sets medical apart from other sectors. The risk management process run under ISO 14971 also determines which tests are required. The test list is not copied from a table of standards; it is derived and justified from the device's intended use, the nature and duration of patient contact, the use environment and foreseeable misuse.
Assessment consists of several separate bodies of work, each with its own set of standards. Biocompatibility runs through the ISO 10993 series, electrical device safety through the IEC 60601 series, sterilisation through ISO 11135/11137/17665, packaging through ISO 11607, software through IEC 62304 and usability through IEC 62366. The quality system (ISO 13485) is the framework that binds these together.
Which tests are required is determined by the device's CLASS and its MODE OF CONTACT WITH THE BODY. A product in brief contact with skin and an implant entering the bloodstream do not go through the same test set; the scope is set by a biological evaluation plan prepared under ISO 10993-1. That plan justifies in writing which endpoints are required and why the others are not.
Packaging and sterilisation are taken as seriously as the device itself in this field. For a sterile device the packaging is not a transport container but the barrier that maintains sterility; if the barrier is breached, the device is no longer sterile. Packaging processes are therefore validated and shelf life is supported by real-time ageing data.
For devices containing software, assessment shifts from testing towards PROCESS assurance. IEC 62304 defines which development and verification steps must be followed according to the safety class of the software; the evidence is the traceability of the development process. Testing software does not make it safe — the process record does.
The clinical side is a separate column of the technical file. Test reports show that the device is technically safe; clinical evaluation establishes that the device delivers the intended clinical benefit and that the benefit-risk balance is acceptable. Neither replaces the other.
Method groups in this field
Biocompatibility
Cytotoxicity, irritation, skin sensitisation, systemic toxicity, haemocompatibility, genotoxicity and local effects after implantation. The required endpoints are set by the ISO 10993-1 plan.
Electrical device safety
IEC 60601-1 basic safety and essential performance; EMC, alarm, usability and environmental requirements through the collateral standards.
Sterilisation validation
Validation of sterilisation processes by ethylene oxide, radiation or moist heat; bioburden and sterility assurance level studies.
Packaging
Integrity of the sterile barrier system, seal strength, distribution simulation and shelf-life studies.
Microbiological tests
Bioburden determination, sterility testing, bacterial endotoxin and, where required, carrier validation studies.
Software and usability
IEC 62304 life cycle evidence and use-error focused evaluation under IEC 62366.
Commonly confused in this field
- Cytotoxicity alone is not evidence of biocompatibility; the required set of endpoints is determined and justified according to ISO 10993-1.
- An ISO 13485 certificate does not confer CE marking; classification under the MDR, the technical file and the notified body process run separately.
- Accelerated ageing does not replace real-time ageing; a shelf life claim is supported by real-time data.
- A change of material (supplier, pigment, sterilisation method) may require the biological evaluation to be repeated; it is not a silent change.
- An assessment made without the collateral and particular standards for IEC 60601-1 is incomplete; which -1-x and -2-x standards were applied must appear in the report.
- In vitro diagnostic devices fall under the IVDR rather than the MDR, and laboratory equipment is often on the IEC 61010-1 side.
Which decisions these results support
- MDR/IVDR technical file and notified body assessment
- Completing the biological evaluation plan
- Sterilisation and packaging validation
- Determining shelf life and storage conditions
- Determining the scope of reassessment after a design change
Related Tests
Frequently Asked Questions About Irritation
What did ISO 10993-23 change?
Skin irritation assessment was separated from ISO 10993-10 and published under ISO 10993-23, with greater emphasis on in-vitro reconstructed human epidermis methods. This is a result of the trend toward reducing animal use.