MIL-STD-461 CS116
EMC / EMI Testleri laboratory work

What Is CS116?

CS116 is a test under MIL-STD-461 in which damped sinusoidal transient pulses are injected into the equipment's cable bundles and power lines to evaluate immunity.

Purpose of CS116

The purpose is to verify that the equipment maintains its function under lightning- and switching-induced oscillatory transients on the platform.

Which Products Is CS116 Applied To?

  • Military electronic units
  • Aerospace avionics
  • Platform power and control systems

In Which Sectors Is CS116 Used?

ElectronicsElectricalAutomotiveTelecommunicationsDefence

Standards Related to CS116

  • MIL-STD-461 CS116

CS116 Conditions

waveform
Damped sine defined in the standard; applied at certain frequencies
peak current
Defined in the standard according to platform type
Number of shocks
Defined number of signals for each frequency and cable
Enjeksiyon
With current probe

Equipment for CS116

  • Damped sinusoid generator
  • Injection and monitoring probes
  • Oscilloscope
  • Function-monitoring system

Sample Requirements for CS116

  • Cable bundles and power lines must be identified
  • The function-monitoring method must be defined
  • Function must be checked before the test

Duration of CS116

Depends on frequency and number of cables; typically one working day.

CS116 Procedure

  1. 1Peak current is set via probe calibration.
  2. 2The probe is placed on the cable bundle.
  3. 3Pulses are applied at each defined frequency.
  4. 4Repeated for each cable.
  5. 5Function is monitored and checked for permanent damage.

CS116 Acceptance Criteria

The acceptance criterion is that no functional degradation or permanent damage occurs.

Evaluation of Results

Immunity may weaken at resonant frequencies; frequencies of degradation are noted in the report.

CS116 Report

  • Applied standard and test code
  • Waveform, frequencies and peak current
  • Cables tested
  • Functional observations

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Defence procurement specifications
  • Aviation platform requirements

EMC / EMI Testleri — What Does This Testing Field Cover?

The section below describes the field that the CS116 test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

EMC testing answers a question with two sides: does the device emit an unacceptable level of electromagnetic interference into its surroundings (emission), and does it withstand the interference coming from them (immunity)? The two sides are measured with separate tests and separate set-ups, and both are required.

The field exists because of a simple physical fact: every conductor carrying current behaves like an antenna. A switched-mode power supply, a motor drive or the clock signal of a microcontroller radiates radio frequency energy even though it was never designed to. The same conductor also works in reverse: an external field induces a voltage across it. In an environment crowded with devices, this mutual effect means devices disturbing one another.

On the emission side, conducted and radiated emission are measured separately. Conducted emission is the interference the device imposes on its mains and communication cables and dominates at lower frequencies. Radiated emission is the field the device releases into the air and comes to the fore at higher frequencies. The two are measured in different set-ups, and the limits vary by product group.

On the immunity side, real-world sources of interference are simulated: electrostatic discharge (human touch), radiated radio frequency fields (a nearby transmitter), electrical fast transients (switching), surges (lightning and mains events), conducted radio frequency, power-frequency magnetic fields, voltage dips and short interruptions.

The standard to be applied depends on WHERE the product is used, and that choice determines the entire outcome. Residential and industrial environments carry different sets of limits; in vehicles the UNECE R10 regime applies rather than CE; for medical devices IEC 60601-1-2 brings additional requirements; and for products containing a radio, radio legislation comes into play and harmonised ETSI standards are used.

In immunity testing the acceptance criterion is a PERFORMANCE CRITERION class, not a binary pass/fail. A device continuing to function without interruption during the test, being temporarily affected and recovering by itself, or recovering only through user intervention are different classes. Which class is acceptable is defined in the product standard; the tolerance for a device carrying a safety function differs from that of a consumer device.

The most common shortcoming of an EMC file is that it covers only one side. A file carrying an emission report alone is not complete in terms of the EMC directive. The second common gap is a test set-up that does not represent actual use: if the device is measured on a bare bench with cables different from its real ones, the result does not carry over to the field.

Method groups in this field

  • Conducted emission

    Interference imposed on the cable through mains and communication ports, measured via an artificial mains network (LISN).

  • Radiated emission

    The field released into the air by the device, measured at a defined distance in an anechoic or semi-anechoic chamber.

  • Harmonics and flicker

    The harmonic content of the current drawn from the mains and voltage fluctuation; the side that affects mains quality.

  • Electrostatic discharge

    Contact and air discharge together with indirect discharge; the most frequently applied immunity test.

  • Radiated and conducted RF immunity

    The device is exposed to a defined field strength and to an RF signal injected into the cable.

  • Mains-borne events

    Electrical fast transients, surges, voltage dips and short interruptions.

Commonly confused in this field

  • An emission report alone does not complete an EMC file; immunity must be demonstrated as well.
  • An FCC report is not accepted in a CE file; the limits, measurement distances and set-ups are different.
  • The EMC Directive does not apply to vehicles; the UNECE R10 regime does. Specifications requiring both together should be reviewed.
  • The warning that a Class A device may cause interference in a residential environment is mandatory in the manual; market surveillance checks that this warning is present.
  • The test set-up is part of the report. If cable type, length or routing changes, the result changes; measurement must be made in the series-production configuration.
  • CISPR 22 and CISPR 13 have been withdrawn; their current counterparts are CISPR 32 and CISPR 35.

Which decisions these results support

  • CE declaration under the EMC Directive
  • The EMC part of radio equipment conformity
  • A UNECE R10 file for a vehicle component
  • Resolving field interference complaints and correcting the design
  • Assessing the EMC impact of a board or wiring-harness change

Related Tests

Frequently Asked Questions About CS116

According to which standard is CS116 made?

CS116 is executed in scope MIL-STD-461 CS116. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does CS116 apply to?

Mainly applied to Military electronic units, Aerospace avionics and Platform power and control systems. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is CS116 done?

The determining parameters are: waveform — Damped sine defined in the standard; applied at certain frequencies, peak current — Defined in the standard according to platform type and Number of shocks — Defined number of signals for each frequency and cable. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for CS116?

Cable bundles and power lines must be identified, The function-monitoring method must be defined and Function must be checked before the test. The number of samples is determined according to the product standard and the scope to be reported.

How long does CS116 take?

Depends on frequency and number of cables; typically one working day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the CS116 result called "appropriate"?

The acceptance criterion is that no functional degradation or permanent damage occurs.