Loading

RF and Wireless Testing · Kablosuz

5G NR — RED

REDETSIFCC
RF and Wireless Testing laboratory work

What Is 5G NR — RED?

5G NR compliance tests examine whether the device's radio interface meets the requirements of the relevant regulation and standards. Measurements fall into two groups: on the transmitter side, output power, spectrum mask, adjacent channel leakage and unwanted emissions; on the receiver side, sensitivity and selectivity.

Purpose of 5G NR — RED

The purpose is to ensure the device transmits within the permitted limits in its own band, does not disrupt services in neighbouring bands, and demonstrates its declared performance.

Which Products Is 5G NR — RED Applied To?

  • 5G smartphones and modems
  • CPE and fixed wireless access devices
  • IoT and industrial 5G modules
  • Automotive telematics units
  • Private network equipment

In Which Sectors Is 5G NR — RED Used?

TelecommunicationsElectronicsAutomotiveMedical Device

Standards Related to 5G NR — RED

  • REDEU radio equipment directive test
  • ETSIEuropean telecommunications standards test
  • FCCUS radio and EMC regulations test

5G NR — RED Conditions

Bantlar
NR bands supported and declared by the device
Transmitter measurements
Output power, spectrum mask, ACLR, spam
Receiver measurements
Reference sensitivity and selectivity
Limits
From the applicable harmonized standard or FCC rule

Equipment for 5G NR — RED

  • 5G NR communication test set (base station emulator)
  • Spectrum and signal analyser
  • Shielded chamber and OTA measurement setup
  • RF cable and attenuator set for conducted measurement
  • Climate chamber (for extreme-condition measurements)

Sample Requirements for 5G NR — RED

  • The sample must be taken so as to represent the batch or production run.
  • Sample description, material type, and production direction if any, must be stated.
  • The standard to be applied and any customer specification must be provided together with the sample.
  • The test may be destructive; the required number of samples must be confirmed in advance.
  • Surfaces that will be tested must be protected during transport.

Duration of 5G NR — RED

Scope depends on the number of supported bands and modes. A limited band set takes days, while the full compliance study for a multi-band device spans weeks.

5G NR — RED Procedure

  1. 1The bands and modes supported by the device are declared.
  2. 2The standard to be applied and the limit set are determined.
  3. 3The device is connected to the test set and communication is established.
  4. 4Transmitter measurements are run on each band.
  5. 5Receiver performance measurements are made.
  6. 6Unwanted emissions are scanned over a wide frequency range.
  7. 7Results are reported compared against the limits.

5G NR — RED Acceptance Criteria

The method standard defines how the test is performed, not what the result must be. The acceptance limit comes from the material or product standard, the customer specification, or the relevant regulation; this page therefore does not give a numerical limit.

Evaluation of Results

The result is assessed by whether the measured values remain within the limits of the applied standard. Limits vary by region: harmonised ETSI standards apply in the EU, FCC rules in the USA; two separate assessments may be needed for the same device.

5G NR — RED Report

  • Sample description, material/product information, and batch number if any
  • Sample preparation method and conditioning conditions
  • Standard and test conditions applied
  • Instrument used and calibration status
  • Measurement results and units
  • Measurement uncertainty (if requested)
  • A statement that the result applies only to the specimen submitted for testing

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Harmonised standards applied according to the product family
  • EU 765/2008 (market surveillance and accreditation framework)
  • Relevant product regulations and customer specifications

RF and Wireless Testing — What Does This Testing Field Cover?

The section below describes the field that the 5G NR test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

RF and wireless testing shows that a device containing a radio uses the spectrum correctly and operates within the limits the relevant legislation allows. This family is a separate body of work from EMC: EMC addresses unwanted interference, whereas here INTENTIONAL emission is assessed.

Spectrum is a public and limited resource, and this determines the legal character of the field. A device spilling outside its permitted band or emitting excess power is not merely a technical defect but a violation that disrupts someone else's service. Radio conformity is therefore policed more strictly than other test fields and markets maintain their own national regimes.

Measurements run separately on the transmitter and receiver sides. On the transmitter side, output power, occupied bandwidth, frequency error, unwanted emissions, adjacent channel power and the power envelope are measured. On the receiver side, sensitivity, selectivity, blocking and spurious response rejection are assessed. The receiver side is often neglected, but in some bands it is a regulatory requirement.

Access protocol specific behaviours are a third axis: listen before talk (LBT), duty cycle, dynamic frequency selection (DFS) and transmit power control (TPC). These mechanisms enable spectrum sharing and it must be shown that they work correctly.

HUMAN EXPOSURE is the fourth axis and one of the most commercially critical. For devices used close to the body, SAR (specific absorption rate) is measured; for devices used at a distance, a field strength assessment is made. Limits and measurement methods vary by market; the same device is assessed separately for Europe and the United States.

Market regimes are decisive in this family and do not substitute for one another: the Radio Equipment Directive and ETSI harmonised standards in Europe, FCC authorisation in the United States (through a TCB for intentional radiators), ISED in Canada, MIC in Japan, KC in South Korea and SRRC in China each carry their own set of requirements. The same device requires a separate file for each market, and some markets impose a local representative or local testing requirement.

Module integration is the subject that raises the most questions in the field. Using a certified radio module does not automatically make the device compliant. A module certificate is valid for a defined antenna, a defined supply and defined conditions of use; if the antenna changes, the layout changes or the module is operated at a different power level, reassessment is required.

The presence of several radios in the same device (Wi-Fi + Bluetooth + cellular + NFC) gives rise to a simultaneous transmission assessment: SAR and unwanted emission measurements are made for the worst case in which the radios operate together.

Method groups in this field

  • Transmitter measurements

    Output power, occupied bandwidth, frequency error, unwanted emissions, adjacent channel power, power spectral density.

  • Receiver measurements

    Sensitivity, selectivity, blocking, spurious response rejection.

  • Spectrum sharing mechanisms

    Verification of listen before talk, duty cycle, dynamic frequency selection and transmit power control.

  • Human exposure

    SAR measurement (handheld and body-worn devices), field strength assessment, multi-radio scenarios.

  • Protocol conformity

    Cellular network conformity testing, Bluetooth and Wi-Fi certification testing, GNSS performance.

  • Antenna measurements

    Gain, radiation pattern, efficiency and total radiated power (TRP) measurements.

Commonly confused in this field

  • Using a certified module does not automatically make the device compliant; if the antenna, layout or power level changes, reassessment is required.
  • An FCC file does not replace a CE file; each market operates its own regime.
  • Receiver side measurements are a regulatory requirement in some bands; measuring only the transmitter produces an incomplete file.
  • SAR limits and measurement methods differ by market; a result in one market does not carry over to another.
  • For devices carrying several radios the simultaneous transmission scenario must be assessed; measuring them individually is not sufficient.
  • Some markets impose local testing or a local representative requirement; technical conformity alone does not secure market access.

Which decisions these results support

  • Market access under radio equipment legislation
  • Verification of the antenna and RF front end design
  • SAR and RF exposure conformity
  • Verification of module integration and the scope of reassessment
  • Determining the worst case in multi-radio scenarios

Related Tests

Frequently Asked Questions About 5G NR — RED

Is RED compliance also valid for the FCC?

No. The two regimes define different limits and different measurement methods. Separate compliance must be demonstrated for each target market.

Is SAR measurement within this scope?

No, it is a separate topic. Human exposure (SAR) is measured separately per its own standards and assessed under RED's health-related article.

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy